NCR-2026-027 Demo Baffle spacing 12mm out at positions 4 and 5
ISO 9001 · LRQA Sun 9 Aug 2026
NCR-2026-027 Closed In-house Rework

Baffle spacing 12mm out at positions 4 and 5

What was found

Tie rod spacers cut from the wrong cut list. Spacing 292mm against 280mm nominal at two positions.

Corrective action

Spacers re-cut and bundle re-stacked. Cut lists now issued per-bundle with the revision on the header.

Raised by Ross Taylor, Leading Hand — Boilermaker, on 18 Jul 2026 · closed 23 Jul 2026.
Detail
Job
JN 174321
Customer
Nestlé Australia
Source
In-house
Cause
Workmanship — wrong cut list
Disposition
Rework
Rework
8.0 h
Cost
$494
Rework hours are booked to the Rework category, which is indirect. They name this job so the cost is attributable, and they never touch the job's quoted manufacturing or testing hours.